Academic Journal

Automated Single-Phase Liquid-Liquid Extraction for Determination of Cr(VI) Using Graphite Furnace Atomic Absorption Spectrophotometry without Wet Digestion of Samples.

Bibliographic Details
Title: Automated Single-Phase Liquid-Liquid Extraction for Determination of Cr(VI) Using Graphite Furnace Atomic Absorption Spectrophotometry without Wet Digestion of Samples.
Authors: Cunha, Francisco, Pereira, Anderson, Fernandes, Julys, Lyra, Wellington, Araújo, Mario, Almeida, Luciano
Source: Food Analytical Methods; Apr2017, Vol. 10 Issue 4, p921-930, 10p
Abstract: This paper proposes a method to perform rapid and sensitive graphite furnace atomic absorption spectrometry (GFAAS) determination of Cr(VI) in vinegar samples without wet digestion. Taking into account low levels of Cr(VI) and the presence of several concomitants in the sample matrix, the proposed method uses single-phase liquid-liquid extraction (SPLLE). The method is automated, employing a flow-batch analyzer (FBA) which uses a mixing chamber designed to emulate a separation funnel promoting the formation/break of the single-phase solution, reaction and extraction. The Cr(VI) extraction procedure was performed by proportioned mixing of the vinegar sample (aqueous phase), amyl alcohol (organic phase), and ethanol (consolute) to form a single-phase solution. The chelating reagent sodium diethyldithiocarbamate (DDTC) dissolved in the consolute reacts rapidly with Cr(VI), in the single phase to produce a stable Cr-DDTC complex. The single-phase break step is performed by adding an excess of Britton-Robinson buffer, and then the organic phase enriched with Cr(VI) was analyzed by GFAAS. Factors such as extraction steps, single-phase composition, pH, chelating agent concentration, and flow-batch parameters were optimized. The FBA-SPLLE-GFAAS was evaluated in vinegar samples showing satisfactory analytical features in terms of limit of quantification (0.86 μg L ), precision (RSD <12 %), characteristic mass (m = 0.32 pg), high sampling rate ( 26 h ), and accuracy (recovery rate = 82-108 %). The proposed method requires one-step extraction and is eco-friendly since it consumes low amounts of non-toxic chemicals and generates little waste (about 700 μL per determination). [ABSTRACT FROM AUTHOR]
Copyright of Food Analytical Methods is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
ISSN: 19369751
DOI: 10.1007/s12161-016-0651-y
Database: Complementary Index