DynaCool : simulating efficient liquid cooling for current and next generation large scale data centres : a thesis submitted to Auckland University of Technology in partial fulfilment of the requirements for the degree of Master of Computer and Information Sciences, 2017 / Nidhi Gowdra ; supervisor: Roopak Sinha.

Energy consumption in Large Scale Data Centres (LSDC's) doubled from 2000 to 2006 reaching 61 TerraWatt-hour (TWh) per year. Most power generation sources are sadly fossil fuelled, which is increasing the effects of anthropomorphic climate change. 99-100% of the energy consumed by IT equipment...

Full description

Saved in:
Bibliographic Details
Main Author: Gowdra, Nidhi (Author)
Corporate Author: Auckland University of Technology. School of Engineering, Computer and Mathematical Sciences
Format: Ethesis
Language:English
Subjects:
Online Access:Click here to access this resource online
Description
Summary:Energy consumption in Large Scale Data Centres (LSDC's) doubled from 2000 to 2006 reaching 61 TerraWatt-hour (TWh) per year. Most power generation sources are sadly fossil fuelled, which is increasing the effects of anthropomorphic climate change. 99-100% of the energy consumed by IT equipment is dissipated as heat from the servers, which creates a real problem of cooling in LSDC's. Air cooling systems in LSDC's are struggling to handle the increased cooling demands, which is why they account for 40% of the total energy consumed. The rest of the energy consumed is used to power the IT equipment and data centre infrastructure facilities like lighting. The ratio of power consumed by the data centre facility to the power consumed by the IT equipment is known as Power Usage Effectiveness (PUE), which is a metric used to measure data centre efficiency. Reducing the PUE by even fractions of percentages can prevent millions of tons of greenhouse gases from being emitted into the atmosphere. One of the methods of reducing PUE is by using alternate forms of cooling technologies like liquid cooling. This thesis explores novel optimisation methods for cooling control in liquid cooled LSDC's. The three strategies focused on are Static Flow Rate, Variable Flow Rate (VFR) and the proposed Pulsed Variable Flow Rate (PVFR) cooling control strategies. The power consumption of coolant pumps and the effect it has on reducing energy consumption and PUE are investigated for all three cooling control strategies using computer simulations. Current simulation software were limited to air cooling and as such we needed to develop a proprietary computer simulation software. The software we developed was DynaCool and the simulation data we gathered was used to analyse the effectiveness of the different cooling control strategies. DynaCool was built using requirements engineering and model driven design to ensure the validity of the software, as these methodologies are commonly used in large complex industrial systems. The data analysed indicated a PUE reduction of at least 15.4% for the novel PVFR liquid cooling control strategy over the static and VFR cooling control strategies. This reduction equates to savings of 2.84 million tons of greenhouse gas emissions and 18.788 TWh of power consumption per year for an adoption rate of 100%. Realistically speaking, an adoption rate of 10% would yield power saving of 1.88 TWh or 284 thousand tons of greenhouse gas emission per year. This adoption rate is easily achievable by the industry as recent trends indicate data centre operators are moving towards alternate cooling technologies. This is evidenced by Google aiming to achieve carbon neutrality by 2017 using liquid cooling technologies.
Author supplied keywords: Data centers; Data centres; Liquid cooling; Large scale; Simulation.
Physical Description:1 online resource
Also held in print (169 leaves : illustrations ; 30 cm) in off-campus storage, box 222.
Bibliography:Includes bibliographical references.
Availability

Online

Click here to access this resource online

Held Offsite

  • Call Number:
    Off-campus storage Box 222
    Copy
    Available - City Offsite Storage
Requests
Request this item Request this AUT item so you can pick it up when you're at the library.
Interlibrary Loan With Interlibrary Loan you can request the item from another library. It's a free service.